Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.956
Filtrar
2.
Int J Pediatr Otorhinolaryngol ; 179: 111902, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38479070

RESUMO

INTRODUCTION: Button battery (BB) ingestion injuries are a devastating and preventable event within the pediatric population. Efforts to reduce the prevalence of esophageal button battery ingestion injuries include primary preventative measures. It is integral to assess the public's baseline knowledge about BB injuries to tailor future primary prevention efforts. METHODS: This is a crowdsourcing survey-based study. Participants were notified through our institution's Twitter and Instagram accounts. RESULTS: There were 930 completed survey responses from May to June 2022. The survey found that 87% (791/910) knew that swallowing a BB could cause injury and 71% knew that it could cause death (642/905). Eight-five percent of respondents did not know what signs and symptoms to look for after BB ingestion, only 30% (99/340) of healthcare professionals felt they would know. Only 10.1% (94/930) of participants knew to give children over 12 months old honey after suspected BB ingestion. Thirty-four percent (311/930) knew that complications could still occur even after BB were removed. Seventy-seven percent (719/930) knew that a dead BB could cause injury but only 17% knew the correct way to dispose of a dead button battery (158/930). Only 8% (72/930) of participants were knew that wrapping dead BB in tape could potentially prevent injury. CONCLUSION: The current study reveals gaps in the public's understanding of BB injury including: the presentation of BB injuries; the delayed harm of BB impactions; management and mitigation strategies, and BB disposal methods. This survey provided imperative insights to help guide future education and primary prevention initiatives.


Assuntos
Doenças do Esôfago , Corpos Estranhos , Mídias Sociais , Criança , Humanos , Lactente , Estudos Transversais , Corpos Estranhos/epidemiologia , Corpos Estranhos/etiologia , Corpos Estranhos/prevenção & controle , Doenças do Esôfago/complicações , Fontes de Energia Elétrica , Ingestão de Alimentos
3.
J Cardiothorac Surg ; 19(1): 101, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38374106

RESUMO

BACKGROUND: Acupuncture, a traditional Chinese medical treatment, has been gaining popularity over the years. However, it also presents certain risks. We report a case of a patient who discovered a foreign body in their lung several years after undergoing acupuncture. CASE PRESENTATION: A middle-aged woman presented to our hospital with chest pain. An X-ray revealed a needle-like foreign body in the middle lobe of her right lung. The patient had previously undergone acupuncture treatment for local pain in her lower back and lower extremities many years prior. Based on the imaging findings and her medical history, we hypothesized that the foreign body in her lung was a result of a dislodged acupuncture needle. Through preoperative 3-dimensional reconstruction and indocyanine green localization, we were able to locate the foreign body in the lateral segment of the right middle lobe. We successfully removed the foreign body via wedge resection, and the patient made a smooth recovery post-surgery. CONCLUSION: Acupuncturists and surgeons should remain vigilant about the potential risks associated with acupuncture.


Assuntos
Terapia por Acupuntura , Corpos Estranhos , Migração de Corpo Estranho , Humanos , Pessoa de Meia-Idade , Feminino , Agulhas/efeitos adversos , Terapia por Acupuntura/efeitos adversos , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/etiologia , Corpos Estranhos/cirurgia , Radiografia , Dor no Peito , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia
4.
Aesthet Surg J ; 44(2): 183-191, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-37863473

RESUMO

BACKGROUND: The injection of illicit, nonregulated foreign materials is increasingly common and has negative consequences relative to the inflammatory process that ensues. OBJECTIVES: The aim of this study was to identify anatomical and imaging characteristics after the cosmetic injection of illicit foreign materials. METHODS: A retrospective review of clinical and imaging records was performed. The issues analyzed were the anatomical site, type of injected substance, imaging method for diagnosis, and patterns of migration. RESULTS: Data on 413 patients were collected. Most patients were female, with a mean age of 44 years. The most commonly infiltrated region was the buttocks (n = 284; 53.58%) followed by the breast (n = 99; 18.67%). Magnetic resonance imaging was the most common method of diagnosis in those patients who had an imaging study (159 out of 168). The most frequent depth of foreign material detected by imaging was the muscular plane (n = 103; 61.30%). Migration was detected in 56.55% of patients who had an imaging study. Most infiltrated substances were unknown; biopolymers were the most commonly identified substances. Depending on the type of substance, migration rates varied from 13% to 29%; rate differences were not statistically significant (P = .712). Migration was more common when the depth of infiltration was in muscle (77.66%) than in subcutaneous tissue (23.4%); this difference was statistically significant (P < .0001). CONCLUSIONS: Deep infiltration is related to greater migration rates, apparently regardless of the substance injected.


Assuntos
Mama , Corpos Estranhos , Humanos , Feminino , Adulto , Masculino , Mama/diagnóstico por imagem , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/etiologia , Nádegas/diagnóstico por imagem , Estudos Retrospectivos , Injeções
5.
J Pediatr Hematol Oncol ; 45(8): e959-e965, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37782316

RESUMO

BACKGROUND: Split/fracture and embolization of central venous/shunt catheters are rare but serious complications in children. Percutaneous retrieval of intravascular foreign bodies is an important minimal invasive treatment. This study is aimed to represent our largest pediatric sample experience till now of 17 years from a single institution. Another aim is to compare the results regarding the removal or leaving in place of embolized or ruptured intravascular or cardiac venous catheter parts in children. PATIENTS AND METHODS: A total of 26 cases were included in this study. Any pediatric patient with normal coagulation parameters and a fractured catheter fragment was included in this study. Other intravascular foreign bodies related to interventional devices and/or pacemaker/implantable cardiac defibrillator leads were excluded from this study. RESULTS: Twenty-six patients, of whom 25 had oncologic diseases and 1 had a ventriculoatrial shunt, were included. The median age was 83.5 months (between 20 mo and 18 y) at treatment.Superior vena cava (9 cases), followed by the right atrium (5 cases), were the most two common sites of embolization for cardiovascular foreign bodies. The success rate of percutaneous retrieval was 92.3% in all patients. There were neither complications nor deaths. The retrieval technique revealed a predisposition for extraction through the femoral vein (96.1%) and using snare techniques (100%). Additional catheters like pigtail, National Institutes of Health, or ablation catheters were used for stabilization in selective cases in which the permanent central venous fragments stuck to the vessels. A tractional maneuver and capturing the ruptured material in the middle were other trick points for successful retrieval. Patients were asymptomatic in 76.9% of cases (20/26). CONCLUSION: Percutaneous retrieval of cardiovascular foreign bodies is a reasonable, safe, and effective way in children when the catheter fragments are free and mobile. It should be considered the preferred treatment option instead of surgery. In patients where catheter fragments are stuck and are adherent to vessels, it could be left, and followed up by anticoagulation. Novel techniques accompanied by an experienced team could be helpful in difficult cases.


Assuntos
Cardiologia , Cateterismo Venoso Central , Corpos Estranhos , Humanos , Criança , Veia Cava Superior , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Corpos Estranhos/etiologia , Corpos Estranhos/terapia , Átrios do Coração , Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos
8.
Laryngoscope ; 133(12): 3358-3360, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37602765

RESUMO

The realization of customized earing plugs and earmolds for hearing aids requires an impression of the external auditory canal to obtain a siliconized mold. Silicone used for ear impressions is known to be safe and inert but deposition of silicone in the middle ear can middle and inner ear damages. We present a case of accidental injection of silicone in the middle ear and the Eustachian tube resulting in an erosion of the carotid canal. Laryngoscope, 133:3358-3360, 2023.


Assuntos
Orelha Interna , Tuba Auditiva , Corpos Estranhos , Humanos , Tuba Auditiva/cirurgia , Orelha Média , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/etiologia , Corpos Estranhos/cirurgia , Silicones/efeitos adversos , Meato Acústico Externo
9.
Neurol Med Chir (Tokyo) ; 63(10): 482-489, 2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37648536

RESUMO

Delayed foreign body reactions to either or both clipping and coating materials have been reported in several small series; however, studies in the titanium clip era are scarce. This study aims to survey the contemporary status of such reactions to titanium clips and coating materials. Among patients who received a total of 2327 unruptured cerebral aneurysmal surgeries, 12 developed delayed intraparenchymal reactions during outpatient magnetic resonance imaging (MRI) follow-up. A retrospective investigation was conducted. The patients' average age was 58.6 (45-73) years, and 11 were women. The aneurysms were located in the middle cerebral artery (n = 7), internal carotid artery (n = 4), or anterior communicating artery (AComA, n = 1). In 10 patients, additional coating with tiny cotton fragments was applied to the residual neck after clipping with titanium clips; however, only the clipping with titanium clips was performed in the remaining two. The median time from surgery to diagnosis was 4.5 (0.3-60) months. Seven (58.3%) patients were asymptomatic, and three developed neurological deficits. MRI findings were characterized by a solid- or rim-enhancing lobulated mass adjacent to the clip with surrounding parenchymal edema. In 11 patients, the lesions reduced in size or disappeared; however, in one patient, an AComA aneurysm was exacerbated, necessitating its removal along with optic nerve decompression. In conclusion, cotton material is a strongly suspected cause of delayed foreign body reactions, and although extremely rare, titanium clips alone may also induce such a reaction. The prognosis is relatively good with steroid therapy; however, caution is required when the aneurysm is close to the optic nerve, as in AComA aneurysms.


Assuntos
Corpos Estranhos , Aneurisma Intracraniano , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Titânio , Estudos Retrospectivos , Instrumentos Cirúrgicos/efeitos adversos , Reação a Corpo Estranho , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/etiologia , Corpos Estranhos/cirurgia
10.
Aesthetic Plast Surg ; 47(6): 2463-2469, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37653179

RESUMO

PURPOSE: The purpose of this study was to summarize the misdiagnosis and treatment of corneal complications associated with suture exposure in cases of buried-suture double-eyelid blepharoplasty. METHODS: This study retrospectively analyzed 14 patients with palpebral conjunctival and corneal complications due to suture exposure after buried-suture double-eyelid blepharoplasty at the First Affiliated Hospital of Harbin Medical University from January 2020 to July 2022. The patients' clinical symptoms included photophobia, lacrimation, pain, foreign body sensation, swelling of the eyelids, conjunctival hyperemia, secretion, etc. We recorded the patient's sex, age, surgical method, length of exposed suture, suture type, number of double-eyelid surgeries, surgical site, timepoint when eye discomfort occurred, misdiagnosed disease and treatment. RESULTS: Three patients were misdiagnosed with dry eye, nine patients were misdiagnosed with viral keratitis, and two patients were misdiagnosed with allergic conjunctivitis. All 14 patients had manifestations of photophobia, lacrimation, pain, foreign body sensation and conjunctival hyperemia. Eight patients had manifestations of swelling of the eyelids. Five patients had manifestations of eye secretions. There were 8 patients with corneal epithelial injuries and 6 patients with corneal ulcers. All patients underwent suture removal without further progression. Ten patients were treated with artificial tears, and 4 patients were treated with calf serum deproteinized gel after suture removal. CONCLUSION: If there is postoperative eye discomfort caused by eyelid and corneal complications in patients after buried-suture double-eyelid blepharoplasty, clinicians should carefully check whether there is suture exposure and determine the cause in a timely manner. Suture removal is the best way to treat this complication. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Blefaroplastia , Corpos Estranhos , Hiperemia , Humanos , Blefaroplastia/efeitos adversos , Blefaroplastia/métodos , Estudos Retrospectivos , Hiperemia/etiologia , Hiperemia/cirurgia , Fotofobia/etiologia , Fotofobia/cirurgia , Técnicas de Sutura , Povo Asiático , Pálpebras/cirurgia , Suturas , Erros de Diagnóstico , Dor/etiologia , Corpos Estranhos/etiologia , Corpos Estranhos/cirurgia
11.
Acta Otorhinolaryngol Ital ; 43(2): 149-154, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37099439

RESUMO

Objectives: In this study, the damage caused by button batteries (BB) trapped in the ear canal (EC) and strategies to reduce this damage before their removal were investigated in vitro. Methods: After four EC models prepared from freshly frozen cadaveric bovine ears were thawed, 3 V lithium BBs were placed in the channels. After a three-hour period of preliminary damage, nothing was applied to the first EC model, the second EC model underwent saline administration, the third EC model underwent boric acid administration, and the fourth EC model underwent the administration of 3% acetic acid. The voltage, tissue temperature, and pH of the BBs were measured. The BBs were removed at the end of the 24th hour, and the EC models were examined by a pathologist. Results: The greatest decrease in pH was detected in the fourth EC model in which acetic acid was administered. The depth of necrosis was 854 µm in the first EC model, 1858 µm in the second EC model, and 639 µm in the third EC model at the end of the 24th hour. No necrosis was detected in the fourth EC model. Conclusions: Lithium BBs can cause alkaline tissue damage in a short time in cadaveric EC models. pH neutralisation strategies appear to be experimentally successful under in vitro conditions.


Assuntos
Corpos Estranhos , Humanos , Animais , Bovinos , Corpos Estranhos/etiologia , Meato Acústico Externo , Lítio , Orelha , Ácido Acético , Necrose/complicações , Cadáver
12.
Am J Emerg Med ; 69: 76-82, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37060632

RESUMO

INTRODUCTION: Presentations to the emergency department for rectal foreign bodies are common, but there is little epidemiologic information on this condition. This limits the ability to provide evidence-based education to trainees regarding the populations affected, the types and frequency of foreign bodies, and factors associated with hospitalization. To address this, we analyzed national estimates of emergency department presentations for rectal foreign bodies from 2012 to 2021 in the US. METHODS: We queried the National Electronic Injury Surveillance System for any injury to the 'pubic region' or 'lower trunk' with an accompanying diagnosis of foreign body, puncture, or laceration. Two authors manually reviewed all clinical narratives to identify cases of rectal foreign bodies. National estimates were determined using weighting and strata variables, incidence rates calculated using census data, trends assessed by linear regression, and factors associated with hospitalization identified by multivariable logistic regression. RESULTS: From 885 cases, there were an estimated 38,948 (95% CI, 32,040-45,856) emergency department visits for rectal foreign bodies among individuals ≥15 years from 2012 to 2021. The average age was 43, 77.8% were male, 55.4% of foreign bodies were sexual devices, and 40.8% required hospitalization. The annual incidence of presentations for rectal foreign bodies increased from 1.2 in 2012 to 1.9 per 100,000 persons in 2021 (R2 = 0.84, p < 0.01). Males have a bimodal age distribution peaking in the fifth decade, while females have a right-skewed age distribution peaking in the second decade. Female sex (odds ratio [OR] 0.4; 95% confidence interval [CI], 0.2-0.6) and, compared to sexual devices, balls/marbles (OR 0.2; 95% CI, 0.05-0.6) or drugs/paraphernalia (OR 0.1; 95% CI, 0.05-0.4) are associated with a reduced odds of hospitalization. CONCLUSIONS: Presentations to the emergency department for rectal foreign bodies increased for males and females from 2012 to 2021 in the United States. These epidemiologic estimates for a complex form of anorectal trauma provide preclinical information for emergency medicine, surgery, and radiology trainees.


Assuntos
Sistema Digestório , Corpos Estranhos , Humanos , Adulto , Masculino , Feminino , Estados Unidos/epidemiologia , Aceitação pelo Paciente de Cuidados de Saúde , Corpos Estranhos/epidemiologia , Corpos Estranhos/terapia , Corpos Estranhos/etiologia , Distribuição por Idade , Serviço Hospitalar de Emergência
14.
Curr Opin Anaesthesiol ; 36(3): 334-339, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36745076

RESUMO

PURPOSE OF REVIEW: Anesthesia for foreign body removal in children can be quite challenging. Even though rigid bronchoscopy is considered the gold standard for foreign body removal, there is increasing evidence for successful foreign body removal using flexible bronchoscopy. This review discusses the recent implications for flexible bronchoscopy for the purpose of foreign body removal and will compare these findings to rigid bronchoscopy. RECENT FINDINGS: During the last few years, several observational studies on foreign body removal by flexible bronchoscopy have been published, with promising results. SUMMARY: Flexible bronchoscopy is a feasible and safe method for removing aspirated foreign bodies in children. In order to improve patient safety during the procedure, it is necessary for a pediatric anesthetist and a pediatric pulmonologist to work closely together. The anesthetist can take care of the administration of the anesthetic and maintenance of the vital functions, and the pulmonologist can carry out a safe and fast bronchoscopy. In the case of foreign body removal by flexible bronchoscopy, the anesthesiological procedure of choice should be general anesthesia with controlled ventilation via a laryngeal mask.


Assuntos
Broncoscopia , Corpos Estranhos , Criança , Humanos , Broncoscopia/efeitos adversos , Broncoscopia/métodos , Anestesia Geral , Respiração Artificial , Corpos Estranhos/etiologia , Corpos Estranhos/cirurgia , Traqueia/diagnóstico por imagem , Traqueia/cirurgia
15.
Laryngoscope ; 133(10): 2553-2557, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36688270

RESUMO

OBJECTIVE: The treatment of nasal foreign bodies involves safe and reliable removal. Few reports have investigated the relationship between equipment and the incidence of complications. METHODS: This retrospective study included 300 patients with nasal foreign bodies (average: 3.28 years, interquartile range: 2-4 years). Patients' background, characteristics of nasal foreign body, equipment to remove the nasal foreign body, and complications were obtained from medical records. Statistical analysis was performed using Pearson's chi-square test for associated factors and the incidence of epistaxis among the complications. RESULTS: Nasal foreign bodies were found and removed in 256 patients. Forceps, hooks, suction, modified paper clips, and cotton swabs were mainly used to remove the nasal foreign bodies. Epistaxis due to the removal procedure was observed in 26 patients. The occurrence of epistaxis differed depending on the equipment (p = 0.077) and was less frequent in suction and paper clips than in forceps (p < 0.05 and p = 0.077). Epistaxis was not observed when a cotton swab was used. Aspiration and septal perforation were not observed. A statistical relationship was not detected between the hardness of foreign bodies and the occurrence of epistaxis (p = 0.251). The incidence of epistaxis was higher in cases nasal foreign bodies remained for 1 day and over than in cases foreign bodies were removed within 1 day (p < 0.05). CONCLUSIONS: This study revealed that suction, modified paper clips, and cotton swabs could be beneficial options for minimizing complications in the removal of nasal foreign bodies. LEVEL OF EVIDENCE: 4 Laryngoscope, 133:2553-2557, 2023.


Assuntos
Corpos Estranhos , Nariz , Humanos , Estudos Retrospectivos , Epistaxe/etiologia , Epistaxe/complicações , Instrumentos Cirúrgicos/efeitos adversos , Corpos Estranhos/epidemiologia , Corpos Estranhos/etiologia , Corpos Estranhos/cirurgia
16.
Ann Thorac Cardiovasc Surg ; 29(1): 40-43, 2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-34433728

RESUMO

BACKGROUND: Esophageal foreign body (FB) is usually seen in children, prisoners, or patients with psychiatric disorders, most of which can be removed with endoscope. CASE PRESENTATION: We herein report a mentally normal adult inadvertently swallowing a needle, which pierced through the esophagus into the adventitia of pulmonary artery. Computed tomography angiography confirmed its specific location, and urgently, surgical removal was performed after the endoscopic attempt. The patient recovered well and was discharged without any complication of the esophageal perforation. CONCLUSION: Surgical treatment should be carried out aggressively if the esophageal FB is out of reach for endoscopic removal or if complications cannot be resolved endoscopically.


Assuntos
Perfuração Esofágica , Corpos Estranhos , Criança , Humanos , Adulto , Deglutição , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Resultado do Tratamento , Perfuração Esofágica/etiologia , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/etiologia , Corpos Estranhos/cirurgia
17.
Oral Maxillofac Surg ; 27(3): 433-443, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35661006

RESUMO

PURPOSE: To discuss potential causes of broken dental needles during dental anesthesia and features of this complication, including the anatomical location of fragments in tissues, symptoms, complications, and therapeutic approaches. METHODS: Twelve cases of broken dental needles occurring during dental anesthesia and subsequently referred to Hospital de Base do Distrito Federal, Brazil, between 1992 and 2019 were selected. In addition, similar cases reported in the literature over the past 50 years were reviewed. RESULTS: Needle fractures occur most frequently during inferior alveolar nerve blocks and in younger patients. The leading cause is unexpected patient movement during the anesthetic procedure. The needle fragment is most commonly found in the pterygomandibular space or the deep spaces of the head and neck region. Needle migration is a particular concern; although rare, it is unpredictable and potentially life-threatening. CONCLUSIONS: Needle fracture is an intraoperative complication which has the potential to cause severe patient damage. It is essential that practitioners have knowledge of this possible complication and understand the technical considerations for its prevention. The existing literature and the results of this case series analysis suggest that removal of the fractured needle fragment should be attempted as soon as possible.


Assuntos
Anestesia Dentária , Corpos Estranhos , Bloqueio Nervoso , Humanos , Agulhas/efeitos adversos , Corpos Estranhos/etiologia , Corpos Estranhos/cirurgia , Anestesia Dentária/efeitos adversos , Falha de Equipamento , Bloqueio Nervoso/efeitos adversos
18.
J Laryngol Otol ; 137(9): 1058-1061, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36168724

RESUMO

BACKGROUND: Bronchoscopic removal of a foreign body is a common emergency procedure in paediatric otolaryngology. It is potentially life-threatening, as complete airway obstruction caused by the foreign body can lead to hypoxic cardiac arrest during the manipulation of the object. CASE REPORT: This paper presents a child who had aspirated a foreign body that could not be extracted conventionally via rigid bronchoscopy in the first instance. Subsequently, it was extracted at repeat bronchoscopy under controlled respiratory conditions maintained by an extracorporeal gas exchange circuit - extracorporeal membrane oxygenation, using a polypropylene hollow fibre oxygenator commonly employed in cardiac surgery (rather than a more expensive polymethyl pentene oxygenator commonly used in extracorporeal membrane oxygenation). CONCLUSION: Extracorporeal membrane oxygenation use can be considered in exceptional cases of upper airway emergencies, even in resource-poor settings, and can avoid more hazardous thoracotomy and bronchotomy procedures.


Assuntos
Obstrução das Vias Respiratórias , Oxigenação por Membrana Extracorpórea , Corpos Estranhos , Humanos , Criança , Oxigenação por Membrana Extracorpórea/métodos , Traqueia , Broncoscopia/métodos , Obstrução das Vias Respiratórias/etiologia , Corpos Estranhos/etiologia
19.
Jt Comm J Qual Patient Saf ; 49(1): 3-13, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36334991

RESUMO

BACKGROUND: Unintentional retention of surgical items is severe but preventable patient harm in surgical procedures. One multicenter health care organization experienced a harm event due to retained surgical items (RSIs) every eight days in 2019-2020. The research team sought to reduce the incidence of harm due to RSIs, improve near-miss reporting, and increase process reliability in operating rooms across the organization. METHODS: A total of 114 health care facilities in the organization were invited to participate in a multistate, multicenter patient safety initiative to reduce patient harm caused by RSIs. A national-level workgroup comprising various disciplines proposed an evidence-based best practice bundle with five elements: surgical stop, surgical debrief, visual counter, imaging, and reporting of deviations. The workgroup ensured that extensive education and support were accessible to all the participating sites. The researchers monitored the process reliability of bundle elements and improvement milestones of all the sites, along with rates of harm related to RSIs. RESULTS: Implementing the evidence-based RSI reduction bundle across 114 health care facilities resulted in a 14.3% reduction in the rate of harm caused by RSIs and a 59.1% increase in RSI near-miss reporting. The compliance to the RSI bundle reached an average of 70.5%, and 63.2% of the facilities are actively performing Plan-Do-Check-Act (PDCA) cycles to improve bundle compliance continually. CONCLUSION: Implementation of an RSI bundle can be done reliably, can improve near-miss reporting, and can reduce patient harm. Variation in process reliability between centers suggests the significance of overcoming cultural and organizational barriers.


Assuntos
Corpos Estranhos , Dano ao Paciente , Humanos , Reprodutibilidade dos Testes , Segurança do Paciente , Salas Cirúrgicas , Corpos Estranhos/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...